Characteristics and performance

High-performance Armorlene® materials, like HLX, provide outstanding wear and extrusion-resistance properties as well as large range of temperature and media compatibility. The P54 has a proven design pedigree as a high-performance seal used in demanding applications.

The standard P54 seal face includes pressure notches, which makes the seal very responsive to changes in pressure or direction of travel. Used successfully for years in performance-critical applications in construction equipment, machine tools, material handling, agricultural equipment, and other industries, the Hallite P54 is a workhorse compact, double- acting, piston-sealing solution.

The seal’s design fits a variety of housing sizes, including ISO 7425-1 grooves, and is offered in a wide range of metric and inch options. Hallite recommends proper guidance be used with this seal in heavy-duty applications (see Hallite Bearings section).

Product details

This seal is available in a variety of Hallite’s high-performance Armorlene® and Hythane® materials to suit a wide range of demanding applications.

The part numbers listed below only show standard material options for both the face seal and energizer, where applicable. For a complete list of the material and energizer options along with part numbering structure, please see the complete PDF datasheet or click P54 Data Tables.
Ask an expert

Max pressure *

600 Bar

Temp range

-45°C
200°C

Max speed

4m/sec

* Max pressure stated is dependant on the material variant selected. Please consult the datasheet for further information.

Key:
  • Recomended
  • Possible
  • Not suitable

* For fluid types marked as possible, please call our team of experts on +86 (0)21 3351 7272 to talk through your requirements and determine if this seal is the most suitable for your needs.

 Dynamic applicationStatic application
Fluids based on mineral oil  
AnyRecommendedPossible
Waterbased fluids  
HFA (5/95)PossiblePossible
HFB (60/40 invert emulsion)PossiblePossible
HFC (water glycol)PossiblePossible
WaterPossiblePossible
Other fluid types  
Air/NitrogenPossibleNot suitable
HFD (Phosphate ester ARYL Type)Not suitableNot suitable
Synthetic esters (HEES, HFDU)RecommendedPossible