Characteristics and performance

The Hallite EXF is a double-acting, twin o-ring energized, rod wiper designed to include two different unique wiping geometries. The two lips combine to scrape debris from the rod and contain residual oil on rod extension, as well as allowing oil to pump back into the cylinder. The o-ring energizers provide the force necessary to maintain the engagement of the wiping lips against the sliding surface and allow the wiper to adjust for deflection.

Typically made from exclusive Hallite Armorlene® materials, this seal is capable of high speed applications and eliminates any potential for stick-slip. High-performance Armorlene® materials, like HLX, provide outstanding wear and scraping capability as well as large range of temperature and media compatibility.

The Halite EXF works well paired with rod seals that support the requisite dynamic pressure pump-back, like the Hallite R16 rod seal. When paired, they produce a sealing system capable of handling higher speeds, a large range of fluid compatibilities, and temperature range of service. For other rod seal arrangements with EXF, it is necessary to make sure the rod seal will provide proper pressure pump-back, or alternatively vent the system.  Though it is easier to install in the groove, care must be taken to ensure it is not installed backwards and to ensure the proper fit of three individual components.

Product details

The part numbers listed below only show standard material options for both the face seal and energizer, where applicable. For a complete list of the material and energizer options along with part numbering structure, please see the complete PDF datasheet or click EXF Data Tables.
Ask an expert

Temp range

-45°C
200°C

Max speed

15m/sec

* Max pressure stated is dependant on the material variant selected. Please consult the datasheet for further information.

Key:
  • Recomended
  • Possible
  • Not suitable

* For fluid types marked as possible, please call our team of experts on +86 (0)21 3351 7272 to talk through your requirements and determine if this seal is the most suitable for your needs.

 Dynamic applicationStatic application
Fluids based on mineral oil  
AnyRecommendedPossible
Waterbased fluids  
HFA (5/95)PossiblePossible
HFB (60/40 invert emulsion)PossiblePossible
HFC (water glycol)RecommendedPossible
WaterPossiblePossible
Other fluid types  
Air/NitrogenPossiblePossible
HFD (Phosphate ester ARYL Type)Not suitableNot suitable
Synthetic esters (HEES, HFDU)RecommendedPossible