Characteristics and performance

The Hallite ELA rod wiper/excluder uses a single aggressive wiping lip that provides ingression protection. The ELA wiper uses an o-ring energizer to keep the wiper centered, helping to compensate for potential side-to-side movement in the application. Typically made from exclusive Hallite Armorlene® materials, this seal is capable of high-speed applications and eliminates any potential for stick-slip.

Product details

The part numbers listed below only show standard material options for both the face seal and energizer, where applicable. For a complete list of the material and energizer options along with part numbering structure, please see the complete PDF datasheet or click ELA Data Tables.
Ask an expert

Temp range

-45°C
200°C

Max speed

4m/sec

* Max pressure stated is dependant on the material variant selected. Please consult the datasheet for further information.

Key:
  • Recomended
  • Possible
  • Not suitable

* For fluid types marked as possible, please call our team of experts on (02) 8886 1600 to talk through your requirements and determine if this seal is the most suitable for your needs.

 Dynamic applicationStatic application
Fluids based on mineral oil  
AnyRecommendedPossible
Waterbased fluids  
HFA (5/95)PossiblePossible
HFB (60/40 invert emulsion)PossiblePossible
HFC (water glycol)RecommendedPossible
WaterPossiblePossible
Other fluid types  
Air/NitrogenPossiblePossible
HFD (Phosphate ester ARYL Type)Not suitableNot suitable
Synthetic esters (HEES, HFDU)RecommendedPossible